An alternative proposal for HVDC transmission systems using 24-pulse AC/DC converters based on three-winding non-conventional transformers
| dc.contributor.author | OGOULOLA, christel enock ghislain | |
| dc.contributor.author | Rezeck, Angelo José Junqueira | |
| dc.contributor.author | FIFATIN, François-Xavier | |
| dc.date.accessioned | 2026-06-02T16:06:57Z | |
| dc.date.available | 2026-06-02T16:06:57Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | In order to promote savings on installed filters in traditional HVDC transmission systems, and thus provide a less polluted power quality, this paper proposes a 24-pulse controlled converter that uses two identical three-phase three-winding special transformers, as well as four thyristor-controlled 6-pulse AC/DC converters connected in series. The configuration of the two transformers, and the necessary tap calculations are presented in order to achieve the 7.5° phase lag required to obtain the 24-pulse converter system. An analysis of the performance indices (power factor and Total Harmonic Distortion – THD) of both HVDC systems (traditional 12-pulse and the proposed 24-pulse) is performed and the results show improvements in the indices when using the proposed 24pulse system. Simulation analysis was performed using Matlab/Simulink software in order to validate the proposed 24-pulse converter for use in HVDC transmission systems, considering the operationality of the proposed system under normal and degraded operating conditions. A laboratory prototype was designed and executed based on transformers with extended delta primary windings to validate the proposed 24-pulse converter in terms of harmonic mitigation and improved power quality. The results confirm the viability and applicability of the proposed converter in HVDC transmission systems. | |
| dc.identifier.other | 106230 | |
| dc.identifier.other | BECDB-9352 | |
| dc.identifier.uri | https://dspace.uac.bj/handle/123456789/8360 | |
| dc.language.iso | fr | |
| dc.relation.ispartof | Electric Power Systems Research | |
| dc.subject | HVDC systems Harmonic filter Harmonic mitigation Power factor Special transformers Total harmonic distortion | |
| dc.title | An alternative proposal for HVDC transmission systems using 24-pulse AC/DC converters based on three-winding non-conventional transformers | |
| dc.type | Article |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 76e4dee025f143a5bb66ac80ca442d09.pdf
- Size:
- 2.3 MB
- Format:
- Adobe Portable Document Format