An alternative proposal for HVDC transmission systems using 24-pulse AC/DC converters based on three-winding non-conventional transformers

dc.contributor.authorOGOULOLA, christel enock ghislain
dc.contributor.authorRezek, Angelo José Junqueira
dc.contributor.authorFIFATIN, François-Xavier
dc.contributor.authorSilva, Vinicius Zimmermann
dc.contributor.authorGonzatti, Robson Bauwelz
dc.contributor.authorde Oliveira, José Carlos
dc.contributor.authorDi Lorenzo Correa, Rafael
dc.date.accessioned2026-06-02T16:06:57Z
dc.date.available2026-06-02T16:06:57Z
dc.date.issued2020
dc.description.abstractIn order to promote savings on installed filters in traditional HVDC transmission systems, and thus provide a less polluted power quality, this paper proposes a 24-pulse controlled converter that uses two identical three-phase three-winding special transformers, as well as four thyristor-controlled 6-pulse AC/DC converters connected in series. The configuration of the two transformers, and the necessary tap calculations are presented in order to achieve the 7.5° phase lag required to obtain the 24-pulse converter system. An analysis of the performance indices (power factor and Total Harmonic Distortion – THD) of both HVDC systems (traditional 12-pulse and the proposed 24-pulse) is performed and the results show improvements in the indices when using the proposed 24-pulse system. Simulation analysis was performed using Matlab/Simulink software in order to validate the proposed 24-pulse converter for use in HVDC transmission systems, considering the operationality of the proposed system under normal and degraded operating conditions. A laboratory prototype was designed and executed based on transformers with extended delta primary windings to validate the proposed 24-pulse converter in terms of harmonic mitigation and improved power quality. The results confirm the viability and applicability of the proposed converter in HVDC transmission systems.
dc.identifier.doi10.1016/j.epsr.2020.106230
dc.identifier.otherBECDB-12852
dc.identifier.urihttps://dspace.uac.bj/handle/123456789/11081
dc.language.isofr
dc.relation.ispartofElectric Power Systems Research (Elsevier)
dc.subjectHVDC systems
dc.subjectHarmonic filter
dc.subjectHarmonic mitigation
dc.subjectPower factor
dc.subjectSpecial transformers
dc.subjectTotal harmonic distortion
dc.titleAn alternative proposal for HVDC transmission systems using 24-pulse AC/DC converters based on three-winding non-conventional transformers
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
52c313b9f5334f8e0f605025945180c0.pdf
Size:
3.1 MB
Format:
Adobe Portable Document Format

Collections